07/08/19
Message Overview:
| DDG Reference: | 21-62-06 |
| Pilot Action (QRH): | ENVR 06-22 |
| System Description: | 21-53-00 |
| Schematic Diagram: | 21-53-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-52-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The RAM AIR Pushbutton of the BLEED AIR Control Panel is not set to the ON position.
Possible Causes:
- RAM AIR Pushbutton/BLEED AIR Control Panel
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Switch/Lights | AMM 20-11-02-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Switch/Lights | AMM 20-11-02-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Air Control Panel | AMM 36-11-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Air Control Panel | AMM 36-11-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram 36-11 | WM 36-11 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the BLEED AIR control panel, make sure that the RAM AIR pushbutton switch is not set to ON
- Swap PBAs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- On the BLEED AIR control panel, perform wiring checks for an open circuit between the pins of the connectors and aircraft ground that follow:
AP8J1 AIRCRAFT GROUND pin 7 Ground - If there is continuity to ground, continue.
- If there is no continuity to ground, go to step 5.
- Replace BLEED AIR control panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- If there is no continuity, repair or replace the associated wiring.
- Do close out.