Reset of the Potable Water System (EIB)
Click on the following link for procedures to reset the Potable Water System:
Water Tank Level Sensor Torque
An electrical short condition could be caused by over torquing and cracking the sensor during installation, causing water infiltration in the internal circuitry.
Refer to the following for more information:
Potable Water System Vent Valve Cleaning Procedure
It is recommended to perform cleaning of the vent valves before sanitization, or as required if the source of the water is from a region having a high concentration of minerals in the water. This procedure is also applicable if a leak is detected at the vent valve.
Refer to the following for more information:
Waste Disposal System
MAGAIR Toilet (A/C 9002 to 9153)
- This is a complete guide to troubleshoot the MAGAIR toilet
- AW700-38-0672 - Waste System - Magair Toilet Assembly - Reliability Improvement.
EnviroVac Toilet (G5000 - Global XRS)
Potable Water System Turning Off
If the potable water system turns ON and OFF, make sure to check the Galley touchscreen for any maintenance alerts concerning the water Sterilizer. If the water Sterilizer is detected faulty, the water system will shut down. Most aircraft have a function on the galley touchscreen to bypass the Sterilizer inhibit.