Message Overview:
| DDG Reference: | 26-12-01 |
| Pilot Action (QRH): | ADVISORY 6-2 |
| System Description: | 26-21-00 |
| Schematic Diagram: | 26-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
FIDEEX has detected an open circuit in one of the two APU squib bridge circuit of Fire Bottle 2.
Possible Causes:
- Fire Bottle 2 APU Squib
- Fire Detection and Extinguishing (FIDEEX) Control Unit (CU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
WARNING: BEFORE YOU REMOVE/CONNECT ELECTRICAL CONNECTORS FROM/TO THE FIDEEX SYSTEM, MAKE SURE THAT YOU REMOVE ALL ELECTRICAL POWER FROM THE FIDEEX SYSTEM. KEEP THE ELECTRICAL POWER OFF UNTIL ALL CONNECTORS ARE SAFELY ATTACHED AND NO PERSONS ARE IN THE AFT EQUIPMENT COMPARTMENT. YOU DO THIS TO MAKE SURE THAT THE DISCHARGE CARTRIDGES DO NOT FIRE ACCIDENTALLY.
THE DISCHARGE CARTRIDGES ARE ELECTRICALLY-FIRED EXPLOSIVE DEVICES WHICH CAN ACCIDENTALLY ENERGIZE. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO THE EQUIPMENT.
Quick Links:
| Removal of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire Detection and Extinguishing (FIDEEX) Control Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Discharge Cartridges | AMM 26-21-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Discharge Cartridges | AMM 26-21-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
WARNING: INSTALL A CARTRIDGE SHIELD ON THE RECEPTACLE OF THE DISCHARGE CARTRIDGE IMMEDIATELY AFTER YOU DISCONNECT THE ELECTRICAL CONNECTOR. THE DISCHARGE CARTRIDGE IS AN ELECTRICALLY-FIRED EXPLOSIVE DEVICE WHICH CAN ACCIDENTALLY ENERGIZE. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
- Perform wiring check between FIREX Bottle 2 (A112P3) and FIDEEX CU (A106P2). Repair as required.
- If system checks are good, do the close out.
- If fault remains, continue with next step.
- Replace the Discharge Cartridges on FIREX Bottle 2 (APU Discharge).
- If system checks are good, do the close out.
- If fault remains, continue with next step.
- Replace FIDEEX CU.
- Do close out.