02/22/21
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ABNORM 8-18 |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
SPC Channel A or Channel B shows that the SPC is not serviceable because of a fault condition.
Possible Causes:
- Stall Protection Computer (SPC) (one channel defective)
- Angle of Attack Sensor (AOA) (both resolvers of one AOA are defective)
- Pitch Disconnect Solenoid
- One Stick Pusher
- Lost of ARINC data input from at least two Micro Air-Data Computers (MADC)
- Wrong strapping parity or Associated wiring defective between SPC and one of external sensors
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0275 - 'STALL PROTECT FAIL' Nuisance CAS Message
- AW700-27-0363 - No Fault Found (NFF) initiative: Stall Protection Computer (SPC)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of MADC | AMM 34-11-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of MADC | AMM 34-11-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of AOA Sensors | AMM 27-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of AOA Sensors | AMM 27-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Stick Pusher Actuator | AMM 27-32-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Stick Pusher Actuator | AMM 27-32-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Stick Pusher Capstan | AMM 27-32-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Stick Pusher Capstan | AMM 27-32-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using the PMAT, access the Active Faults/Stored Faults as per AMM Tasks.
- Select related CAIMS message below: