07/17/19
Message Overview:
| DDG Reference: | None |
| Pilot Action (QRH): | ADVISORY 7-5 |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-07 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
SPC channel A or channel B shows that the mach transducer is defective or does not give out correct data.
Possible Causes:
- Mach Transducer
- Integrated Electronic Standby Instrument (IESI)
- Stall Protection Computer (SPC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The Mach transducer and source select panel are removed with the installation of the Integrated Electronic Standby Instrument (IESI) and is the baseline installation on aircraft S/N 9159 and subs.
Quick Links:
| Removal of Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of Mach Transducer | AMM 27-32-13-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of Mach Transducer | AMM 27-32-13-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] ] |
Troubleshooting Recommendations:
- Select related CAIMS message below: