Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/22/19

Message Overview:

R FUEL RECIRC ON
(Status)

DDG Reference: 28-24-01
Pilot Action (QRH): STATUS - 3
System Description: 28-26-00
Schematic Diagram: 28-26-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-26-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
71-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

R FUEL RECIRC ON (Status) shows when the conditions that follow occur:

  • The R RECIRC switch/light on the FUEL control panel is set to ON.
  • The right FRTT shut-off valve is open.
  • The right engine fuel return to tank system is commanded on.
  • The engine fuel flow is not less than 2,000 lb/hr (910 kg/hr).

This troubleshooting applies when it is not under normal conditions.

NOTE: This troubleshooting sheet is for Global Express 9002 through 9110 not incorporating SB 700-28-034. This troubleshooting sheet is for the aircraft with the manual Fuel Return To Tank (FRTT) system.

Possible Causes:

  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • FUEL Control Panel (AP5)
  • Ground Stud (GS160)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the FUEL Control Panel AMM 28-20-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the FUEL Control Panel AMM 28-20-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Fuel Management and Quantity Gauging Computer (FMQGC) AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Management and Quantity Gauging Computer (FMQGC) AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

The R FUEL RECIRC ON (Status) CAS does not display when the R RECIRC INHIBIT switch is turned "ON".

NOTE: This troubleshooting sheet is for Global Express 9002 through 9110 not incorporating SB 700-28-034. This troubleshooting sheet is for the aircraft with the manual Fuel Return To Tank (FRTT) system.

  1. Gain access to the FMQGC (A47) and remove FMQGC from the tray.
  2. Perform the wiring continuity test per the table below:

    SWITCH POSITION FROM TO EXPECTED RESULT RESULT
    R RECIRC SW DEPRESSED (ON) A47AP1 - K11 Airframe Ground Continuity

    1. If the wiring check is good, go to step 6.
    2. If the wiring check is not good, then continue with next step.

  3. Remove the fuel control panel (AP5), and disconnect AP5P2.
  4. Perform the wiring continuity test per the table below:

    FROM TO EXPECTED RESULT RESULT
    AP5J2 - 26 AP5J2 - 18 Continuity
    AP5P2 - 18 Airframe Ground Continuity

    1. If the wiring from AP5J2 - 26 to AP5J2 - 18 is not good, then suspect the R RECIRC Switch (SDS6) or the Fuel Control Panel.
    2. If the wiring from AP5P2 - 18 to airframe ground is not good, then repair or replace wiring to GS160 or GS160.
    3. If the wiring check is good, continue with the next step.

  5. Perform the wiring continuity test per the table below:

    FROM TO EXPECTED RESULT RESULT
    A47AP1 - K11 AP5P2 - 26 Continuity

    1. If the wiring check is good then continue with the next step.
    2. If the wiring from A47AP1 - K11 to AP5P2 - 26 is not good, repair or replace wiring from Fuel Control Panel to the FMQGC.

  6. Re-install or re-rack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?

    1. If the CAS does not display, then go to next step.
    2. If the CAS displays, then do close out.

  7. Suspect the FMQGC (A47).
  8. Do close out.