ACPC Cards Isolation Procedure
WARNING: Always remove power from the aircraft before removing and installing ACPC cards during this procedure. Failure to do so could cause injury to personnel and damage to the equipment.
- Remove all cards from the ACPC.
- Re-install:
- Supervisor card (This card is needed at all times)
- Re-install:
- L/H microprocessor
- Primary Logic Card 1 (PLC 1)
- On the L/H EMS CDU access the signboard menu, press on the SYSTEM key and select COUNTERS. Verify the following Counter:
| EMS CDU |
COUNTER |
VALUE |
| LH |
ACPC IN |
|
- If Counter is not 0, continue with next step
- If counter is 0, remove cards installed in step 3 and continue with next step.
- Re-install:
- On RH EMS CDU (or both EMS CDU depending if LH Micro is still in), verify the following Counter:
| EMS CDU |
COUNTER |
VALUE |
| LH |
ACPC IN |
|
| RH |
ACPC IN |
|
- If Counters are not 0, continue with next step
- If counters are 0, remove cards installed in step 5 and continue with next step.
- Re-install:
- EXT AC/DC converter card
- PLC 2
- On both EMS CDU, verify the following Counters:
| EMS CDU |
COUNTER |
VALUE |
| LH |
ACPC IN |
|
| RH |
ACPC IN |
|
- If Counters are not 0, continue with next step
- If counters are 0, remove cards installed in step 7 and continue with next step.
- Re-install:
- Solid State Power Controller (SSPC) cards (one at a time)
- On both EMS CDU, verify the following Counters:
| EMS CDU |
COUNTER |
VALUE |
| LH |
ACPC IN |
|
| RH |
ACPC IN |
|
- If Counters are not 0, continue with the installation of all SSPC cards 1 by 1 and check counter after each installation.
- If counters are 0, remove the SSPC card just installed. Validate that the counters are not at 0 and continue with the other SSPC cards installation.
- Re-install the remaining ACPC cards that have not been installed yet in this procedure
- On both EMS CDU, verify the following Counters:
| EMS CDU |
COUNTER |
VALUE |
| LH |
ACPC IN |
|
| RH |
ACPC IN |
|
- If Counters are not 0, continue with the installation of the remaining cards 1 by 1 and check counter after each installation.
- If counters are 0, remove the card just installed. Validate that the counters are not at 0 and continue with the cards installation.
- At the end, if one or more card was removed and the counters are currently not 0, install the remaining cards 1 at the time to find out which one(s) is(are) causing the counters to be at 0.
- Replace faulty cards.
- Do close out.