ARINC 429 DATA BUS WORD 350 MAINTENANCE CODE DEFINITION TABLE
| ARINC 429 DATA BUS WORD 350 MAINTENANCE CODE DEFINITION TABLE | |
|---|---|
| BIT | DEFINITION |
1 2 |
Octal 3: 1 1 |
3 4 5 |
Octal 5: 1 0 1 |
6 7 8 |
Octal 0: 0 0 0 |
9 10 |
Source/Destination Identifier - (Bit 10 is MSB and Bit 9 is LSB): Bit 10 = 0 and Bit 9 = 0 for Not Used Bit 10 = 0 and Bit 9 = 1 for Left Unit (modulation frequency strapped for 50 Hz) Bit 10 = 1 and Bit 9 = 0 for Right Unit (modulation frequency strapped for 51 Hz) Bit 10 = 1 and Bit 9 = 1 for Center Unit (modulation frequency strapped for 49 Hz) |
| 11 | 0 = Altimeter OK, 1 = Altimeter Error |
| 12 | 0 = RAM OK, 1 = RAM Error |
| 13 | 0 = ROM OK, 1 = ROM Error |
| 14 | Reserved |
| 15 | Reserved |
| 16 | Reserved |
| 17 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 18 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 19 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 20 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 21 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 22 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 23 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 24 | Fault code, refer to ARINC 429 Data Bus Word 350 Diagnostic Code Definitions Table for description |
| 25 | Reserved |
| 26 | Reserved |
| 27 | 0 = Maintenance log not full, 1 = Maintenance log full |
| 28 | 0 = Maintenance log has no data, 1 = Maintenance log has data |
| 29 | Reserved |
30 31 |
Sign/Status Matrix - (Bit 31 is MSB and Bit 30 is LSB): Bit 31 = 0 and Bit 30 = 0 for Failure Warning Bit 31 = 0 and Bit 30 = 1 for No Computed Data Bit 31 = 1 and Bit 30 = 0 for Functional Test Bit 31 = 1 and Bit 30 = 1 for Normal Operation |
| 32 | Parity Bit (UART set for odd parity) |