REPORTED FAULT CONDITION CODES TABLE
| REPORTED FAULT CONDITION CODES TABLE | ||
|---|---|---|
| OUTPUT VOLTAGE (P1-57/59) |
INDICATED ALTITUDE | FAULT REPORTED |
| ALT-4000 antenna monitoring function enabled (P1-21 ground) with ANT-52 antenna | ||
| +2.4 VDC +4.4 VDC +6.4 VDC +8.4 VDC +10.4 VDC +10.7 VDC +11.0 VDC +11.3 VDC +11.6 VDC +11.9 VDC +12.2 VDC +12.5 VDC +12.8 VDC +13.1 VDC +13.4 VDC |
100 feet 200 feet 300 feet 400 feet 500 feet 600 feet 700 feet 800 feet 900 feet 1000 feet 1100 feet 1200 feet 1300 feet 1400 feet 1500 feet |
Antenna Fault Power Supply Fault Antenna Fault + Power Supply Fault Invalid Strap Antenna Fault + Invalid Strap Power Supply Fault + Invalid Strap Antenna Fault + Power Supply Fault + Invalid Strap Internal Fault Antenna Fault + Internal Fault Power Supply Fault + Internal Fault Antenna Fault + Power Supply Fault + Internal Fault Invalid Strap + Internal Fault Antenna Fault + Invalid Strap + Internal Fault Power Supply Fault + Invalid Strap + Internal Fault Antenna Fault + Power Supply Fault + Invalid Strap + Internal Fault |
| ALT-4000 antenna monitoring function left disabled (P1-21 open) | ||
| +4.4 VDC +8.4 VDC +10.7 VDC +11.3 VDC +11.9 VDC +12.5 VDC +13.1 VDC |
200 feet 400 feet 600 feet 800 feet 1000 feet 1200 feet 1400 feet |
Power Supply Fault Invalid Strap Power Supply Fault + Invalid Strap Internal Fault Power Supply Fault + Internal Fault Invalid Strap + Internal Fault Power Supply Fault + Invalid Strap + Internal Fault |
| NOTE: The output voltages and indicated altitude readings shown in bold represent the four basic monitored functions described below:
|
||