Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/11/25

Message Overview:

Message Name:

[ACSC1-B] LH PCK IN TEMP SENS /WRG

Message Code:

2162425ECS

Associated CAS:

L PACK AUTO FAIL
(Caution)

L PACK FAULT
(Advisory)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-51-00 - Filtering and Flow Control System
Schematic Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ] 21-51-00 - Air Conditioning Filtering And Flow Control System - Electrical Schematic
Wiring Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ] 21-51-01 - Filtering And Flow Control System - Control Sensing Left

Message Description:

Left Pack Inlet Temperature Sensor has been detected out of range by Air Conditioning Controller (ACSC) 1 Channel B.

Possible Causes:

  • Pack Inlet Temperature Sensor (PITS) 1 (E23)
  • Air Conditioning System Controller (ACSC) 1 (A87)
  • Temperature Control Thermostat (THC) Filter
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Removal of the Pack Inlet Temperature-Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-51-21-000-801
Installation of the Pack Inlet Temperature-Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-51-21-400-801
Removal of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-000-801
Installation of the Air-Conditioning System Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-60-21-400-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
Removal of the Temperature Control Thermostat Filter [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-000-802
Installation of the Temperature Control Thermostat Filter [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-400-802
Discard of the Pneumatic Temperature Thermostat (THC) Filter [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM36-11-21-961-801

Troubleshooting Recommendations:

  1. Use the PMAT to access CAIMS System Diagnostics. Select ATA 21 > ASCS 1A (1B, 2A, 2B) > LRU TEST > PACK TEMP. SENSOR DATA. Record sensor data using the ECS data table. Compare values between channels and sides.
    NOTE: Best results are obtained if Air Conditioning system components are allowed to reach ambient temperature.

    1. If only one channel has out of range values, go to step 3.
    2. If both channels of the same ACSC have out of range values, continue with next step.

  2. Swap Pack Inlet Temp Sensors (PITS). Is the fault still present on the same side?

    1. If YES, continue with next step.
    2. If NO, replace defective PITS and do close out.

  3. Perform wiring checks between Pack Inlet Temperature Sensor connector (E23P1) and ACSC 1 connector (A87P2).

    1. If wiring defects are found, repair defective wiring and do close out.
    2. If no defects are found, continue with next step.

  4. Swap ACSC 1 with ACSC 2 to confirm faulty unit and do close out.
  5. Do close out.