06/11/19
Message Overview:
Fault Message:
[ACSC2-A] RH PCK IN FLOW SENS /WRG
Fault Code:
2163414ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-51-00 |
| Schematic Diagram: | 21-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Right Pack Inlet Flow Sensor has been detected out of range by Air-Conditioning System Controller (ACSC) 2.
Possible Causes:
- Pack Inlet Flow Sensor 2 (MT109)
- Junction Box (JB6)
- Air-Conditioning System Controller (ACSC) 2 (A88)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active (Global Express / XRS - 9002 to 9312, 9314 to 9380, 9384 to 9429 and Global 5000 - 9127 to 9383, 9389 to 9400, 9404 to 9431 and 9998)
Forum Articles/Infoservice/Newsletter: None
CAIMS has Pack Pressure Xdcr. Data for ACSC controllers on all 4 channels. This will show sensor data and give you an idea of problem areas.
Quick Links:
| Removal of the Pack Inlet Flow-Sensors | AMM 21-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pack Inlet Flow-Sensors | AMM 21-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 | AMM 24-00-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 | AMM 24-00-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Verify 28 VDC at Pack Inlet Flow Sensor 2, MT109P1-A.
- If there is power, go to step 3.
- If there is no power, continue with next step.
- Perform continuity check of JB6.
- If there is continuity, repair defective associated wiring as required and do close out.
- If there is no continuity, replace JB6 and continue with next step.
- Verify ground at Pack Inlet Flow Sensor 2, MT109P1-B.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap Pack Inlet Flow-Sensor 2 with Pack Inlet Flow-Sensor 1.
- If system checks are good, replace Pack Inlet Flow-Sensor 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between Right Pack Inlet Flow Sensor and ACSC 2.
- If wiring checks are not good, repair defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Replace ACSC 2.
- Do close out.