Message Overview:
Message Name:
[ACSC2-A] RH PACK INLET OVERHEAT
Message Code:
2163514ECS
Associated CAS:
| Reporting LRU: | Air Conditioning System Controller (ACSC) 2 |
| System Description: | 21-51-00 - Filtering And Flow Control System |
| Schematic Diagram: | 21-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
A pack inlet overheat condition has been detected by Air Conditioning System Controller (ACSC) 2A.
Possible Causes:
- Fan Air Valve (FAV) 2 (L28)
- Fan Air Valve (FAV) Sense Line
- Pneumatic Temperature Thermostat (THC) 2 (S13)
- Pneumatic Temperature Control Thermostat (THC) Filter
- Pack Inlet Flow Sensor 2 (MT109)
- Pack Inlet Temperature Sensor 2 (E29)
- Fan Air Duct
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of the Pack Inlet Flow-Sensors | AMM 21-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pack Inlet Flow-Sensors | AMM 21-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Air-Conditioning System Controllers | AMM 21-60-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Air-Conditioning System Controllers | AMM 21-60-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Fan Air Valve | AMM 36-11-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fan Air Valve | AMM 36-11-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Fan Air Valve | AMM 36-11-17-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Temperature Control Thermostat | AMM 36-11-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Temperature Control Thermostat | AMM 36-11-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Temperature Control Thermostat Filter | AMM 36-11-21-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Temperature Control Thermostat Filter | AMM 36-11-21-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access System LRU Diagnostics with pack off and cold, verify if pack inlet temperature sensor and pack inlet flow sensor data is valid and compare with opposite side.
- If data is not valid, go to step 8.
- If data is valid, continue with next step.
- Verify all sense lines for damage or leakage.
- If system checks are good, continue with next step.
- If fault remains, repair as required and do close out.
- Inspect Fan Air Valve sense line to pneumatic temperature thermostat (THC) for leaks.
- If system checks are good, continue with next step.
- If fault remains, repair as required and do close out.
- Remove the Pneumatic Temperature Thermostat Filter. Inspect for clogged filter. Clean/replace filter as required. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Perform operational test of the fan air valve.
- If test passes, do close out.
- If test fails, continue with next step.
- Interchange Pneumatic Temperature Thermostat 2 with Pneumatic Temperature Thermostat 1.
- If system checks are good, replace Pneumatic Temperature Thermostat 2 and do close out.
- If fault remains, continue with next step.
- Inspect Fan Air Duct precooler duct for leaks or obstructions.
- If system checks are good, continue with next step.
- If fault remains, repair as required and do close out.
- Interchange Fan Air Valve 2 with Fan Air Valve 1.
- If system checks are good, replace Fan Air Valve 2 and do close out.
- If fault remains, continue with next step.
- Interchange Pack Inlet Flow Sensor 2 with Pack Inlet Flow Sensor 1.
- If system checks are good, replace Inlet Flow Sensor 2 and do close out.
- If fault remains, continue with next step.
- Interchange Pack Inlet Temperature Sensor 2 with Pack Inlet Temperature Sensor 1.
- If system checks are good, replace Pack Inlet Temperature Sensor 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between Pack Inlet Temperature sensor, Pack inlet flow sensor and ACSC 2.
- If the wiring checks are not good, repair the defective associated wiring and do close out.
- If the wiring checks are good, continue with next step.
- Replace ACSC 2.
- Do close out.