Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/27/20

Message Overview:

Fault Message:

SATELLITE DATA UNIT FAILURE

Fault Code:

2310001SC

Associated CAS:

None

Reporting LRU: Satellite Data Unit (SDU)
System Description: 23-13-00
Schematic Diagram: 23-13-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 23-13-09 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Satellite Data Unit (SDU) has detected an internal failure.

Possible Causes:

  • Satellite Data Unit (SDU) (A228)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

AW 700-23-0584 - Honeywell SDU-600 Obsolescence

AW 700-23-0756 - MCS-7000 Obsolescence

SB 700-23-001 - Modification MCS-6000 SATCOM

SB 700-23-043 - Modification MCS-7000 SATCOM

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Satellite Data Unit AMM 23-13-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Satellite Data Unit AMM 23-13-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Satellite Data Unit SMM 23-15-56-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Satellite Data Unit SMM 23-15-56-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Verify the status of the SATCOM DATA UNIT circuit breaker (CB) on the EMS CDU. Is the CB "IN"?

    1. If YES, continue with next step.
    2. If NO, investigate the reason and set it back in.

  2. Disconnect SDU connector A228CP1. Do a 28 VDC voltage check as follows:

    From To Result
    A228CP1-2 A228CP1-3

    1. If there is 28 VDC, continue with next step.
    2. If there is no 28 VDC, investigate and repair defective associated wiring as required and do close out.

  3. Replace the SDU.
  4. Do close out.