04/27/20
Message Overview:
Fault Message:
LO NOISE AMP UNIT/WIRING
Fault Code:
231000DSC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Diplexer/The Low Noise Amplifier (LNA) has been marked failed by the Satellite Communication (SATCOM) system.
Possible Causes:
- Antenna Control Unit (ACU) (A227)
- Diplexer/Low Noise Amplifier (LNA) (A230)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Diplexer/Low Noise Amplifier | AMM 23-13-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Diplexer/Low Noise Amplifier | AMM 23-13-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Antenna Control Unit | AMM 23-13-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Antenna Control Unit | AMM 23-13-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect LNA connector A230P4 and ACU connector A227P2. Perform a continuity check as follows:
From To Result A230P4-G Ground A230P4-K Ground A230P4-B Ground A230P4-H Ground A230P4-J Ground A230P4-A Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A230P4-G A227P2-N A230P4-K A227P2-P A230P4-B A227P2-m A230P4-H A227P2-W A230P4-J A227P2-X A230P4-A A227P2-k - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace the LNA. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the ACU.