03/30/21
Message Overview:
Message Name:
INERTIAL REFERENCE UNIT
Message Code:
231003
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
A failure related to the data from the Inertial Reference System (IRS) connected to the Satellite Data Unit (SDU) secondary port has been detected by the SDU.
Possible Causes:
- Inertial Reference Unit (IRU) 2 (A33)
- Satellite Data Unit (SDU) (A228)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584
AW 700-23-0756
SB 700-23-001
SB 700-23-043
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Inertial Reference Units (IRU) | AMM 34-45-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inertial Reference Units (IRU) | AMM 34-45-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect IRU 2 connector A33BP1 and SDU connector A228BP1. Perform a continuity check as follows:
From To Result A228BP1-C6 Ground A228BP1-D6 Ground A228BP1-C6 A228BP1-D6 - If there is continuity, repair defective wiring or JB as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228BP1-C6 A33BP1-E5 A228BP1-D6 A33BP1-E6 - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring or JB as required and do close out.
- Swap IRU 2 with IRU 1. Is the fault still present?
- If YES, continue with next step.
- If NO, replace IRU 2 and do close out.
- Replace the SDU.
- Do close out.