04/27/20
Message Overview:
Fault Message:
CAIMS/WIRING
Fault Code:
2310059SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The maintenance function for the Satellite Communication (SATCOM) system does not operate correctly.
Possible Causes:
The maintenance function for the Satellite Communication (SATCOM) system does not operate correctly.
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect SDU connector A228BP1 and DAU connector A18CP1. Perform a continuity check as follows:
From To Result A228BP1-E4 Ground A228BP1-F4 Ground A228BP1-E4 A228BP1-F4 - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228BP1-E4 A18CP1-H8 A228BP1-F4 A18CP1-J8 - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Swap DAU 2 with DAU 4. Is the fault still present?
- If YES, continue with next step.
- If NO, replace DAU 2 and do close out.
- Replace the SDU.
- Do close out.