Message Overview:
Fault Message:
IRU 2/WIRING/SDU
Fault Code:
231005BSC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The databus from Inertial Reference Unit (IRU) 2 is detected inactive or faulty.
Possible Causes:
- Inertial Reference Unit (IRU) 2 (A33)
- Satellite Data Unit (SDU) (A228)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Inertial Reference Units (IRU) | AMM 34-45-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inertial Reference Units (IRU) | AMM 34-45-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect IRU 2 connector A33BP1 and SDU connector A228BP1. Perform a wiring check as follows:
From To Result A33BP1-E5 Ground A33BP1-E6 Ground A33BP1-E5 A33BP1-E6 - If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, continue with next step.
- Perform a wiring check as follows:
From To Result A33BP1-E5 A228BP1-C6 A33BP1-E6 A228BP1-D6 - If the wiring checks are not good, repair defective wiring as required and do close out.
- If the wiring checks are good, continue with next step.
- Swap IRU 2 with IRU 1. Is the fault still present?
- If YES, install the IRUs in their original position and continue with next step.
- If NO, replace IRU 2 and do close out.
- Replace the SDU.
- Do close out.