04/27/20
Message Overview:
Fault Message:
DATA BUS FROM RFU TO SDU/WIRING
Fault Code:
2310067SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Radio Frequency Unit (RFU) databus to the Satellite Data Unit (SDU) is inactive.
Possible Causes:
- Radio Frequency Unit (RFU) (A240)
- Satellite Data Unit (SDU) (A228)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Radio Frequency Unit | AMM 23-13-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Radio Frequency Unit | AMM 23-13-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure the SATCOM FREQ UNIT circuit breaker is set to IN on the cockpit Circuit Breaker Panel (CCBP).
- If the circuit breaker is set to IN, continue with next step.
- If the circuit breaker is not set to IN, set it to in and do close out.
- Disconnect RFU connector A240CP1. Perform a 115 VAC voltage check as follows:
From To Result A240CP1-1 A240CP1-7 - If there is 115 VAC, continue with next step.
- If there is no 115 VAC, investigate wiring interface and power source (AC BUS 1) and do close out.
- Disconnect SDU connector A228BP1 and RFU connector A240AP1. Perform a continuity check as follows:
From To Result A228BP1-E9 Ground A228BP1-F9 Ground A228BP1-E9 A228BP1-F9 - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228BP1-E9 A240AP1-A1 A228BP1-F9 A240AP1-B1 - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace the RFU. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the SDU.
- Do close out.