04/28/20
Message Overview:
Fault Message:
HI PWR AMP OVER TEMP WARNING
Fault Code:
23100C7SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Over temperature warning in High Gain Antenna (HGA) High Power Amplifier (HPA).
Possible Causes:
- Satellite Data Unit (SDU) (A228)
- High Power Amplifier (HPA) (A229)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the High Power Amplifier | AMM 23-13-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the High Power Amplifier | AMM 23-13-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove power from the HPA. Allow enough for the unit to cool down to ambient temperature. Is the fault message still present?
- If YES, go to step 3.
- If NO, continue with next step.
- Apply power back to the HPA and operate to test. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Remove and replace the HPA. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the SDU.
- Do close out.