04/28/20
Message Overview:
Fault Message:
T/P BSU/ACU WRONG A429 SDI CODE
Fault Code:
23100D3SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
In the Satellite Communications (SATCOM) System, the Source-Destination Identifier (SDI) code for the Antenna Control Unit (ACU) is not correct for the specified aircraft configuration.
Possible Causes:
- Printed Circuit Board (PCB5)
- Junction Box (JB6)
- High Power Amplifier (HPA) (A229)
- Satellite Data Unit (SDU) (A228)
- Antenna Control Unit (ACU) (A227)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the High Power Amplifier | AMM 23-13-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the High Power Amplifier | AMM 23-13-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Antenna Control Unit | AMM 23-13-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Antenna Control Unit | AMM 23-13-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 | AMM 24-00-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 | AMM 24-00-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB6 Circuit-Cards | AMM 24-00-14-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB6 Circuit-Cards | AMM 24-00-14-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between ACU (A227P1), JB6 and SDU (A228BP1).
- If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between ACU (A227P1), JB6 and HPA (A229BP1).
- If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace ACU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SDU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace HPA.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PCB5/JB6.
- Do close out.