Message Overview:
Fault Message:
RFU TO HGA HPA CABLE LOSS. WIRING/A
Fault Code:
23100D5SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Radio Frequency Unit (RFU) Coaxial Cable to Attenuator or from Attenuator to High Power Amplifier (HPA) is considered disconnected. For the MCS-7000 installation, the RFU is not external to the Satellite Data Unit (SDU).
Possible Causes:
- Satellite Data Unit (SDU) (A228)
- Radio Frequency Unit (RFU) (A240)
- Radio Frequency (RF) Attenuator (A231)
- High Power Amplifier (HPA) (A229)
- Coaxial Cable
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the High Power Amplifier | AMM 23-13-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the High Power Amplifier | AMM 23-13-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Radio Frequency Unit | AMM 23-13-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Radio Frequency Unit | AMM 23-13-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the RF Attenuator | AMM 23-13-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the RF Attenuator | AMM 23-13-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect SDU connector A228CP1 and RFU connector A240CP1. Perform a continuity check as follows:
From To Result A228CP1-12 Ground A228CP1-12 Shield - If there is continuity, repair defective coaxial cable as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228CP1-12 A240CP1-12 - If there is no continuity, repair defective coaxial cable as required and do close out.
- If there is continuity, continue with next step.
- Reconnect what was disconnected in the previous step. Disconnect RFU connector A240BP1 and RF Attenuator connector A231P1. Perform a continuity check as follows:
From To Result A240BP1-71 Ground A240BP1-71 Shield - If there is continuity, repair defective coaxial cable as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A240BP1-71 A231P1-1 - If there is no continuity, repair defective coaxial cable as required and do close out.
- If there is continuity, continue with next step.
- Reconnect what was disconnected in the previous step. Disconnect RF Attenuator connector A231P2 and HPA connector A229AP1. Perform a continuity check as follows:
From To Result A231P2-1 Ground A231P2-1 Shield - If there is continuity, repair defective coaxial cable as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A231P2-1 A229AP1-71 - If there is no continuity, repair defective coaxial cable as required and do close out.
- If there is continuity, continue with next step.
- A Time Domain Reflectometer (TDR) may also be used to check the integrity of the coaxial cable.
- If defects are found, repair as required and do close out.
- If no defects are found, continue with next step
- Replace the RF Attenuator. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the RFU. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the HPA. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the SDU.
- Do close out.