Message Overview:
Fault Message:
SDU TO RFU CAL. GAIN OUT OF RANGE/W
Fault Code:
23100D7SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Satellite Communications (SATCOM) System operates incorrectly or not at all. Issue detected with the output coaxial of the Satellite Data Unit (SDU) to the Radio Frequency Unit (RFU).
Possible Causes:
The Satellite Communications (SATCOM) System operates incorrectly or not at all. Issue detected with the output coaxial of the Satellite Data Unit (SDU) to the Radio Frequency Unit (RFU).
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Radio Frequency Unit | AMM 23-13-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Radio Frequency Unit | AMM 23-13-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect SDU connector A228CP1 and RFU connector A240CP1. Inspect the Coaxial cable connector on both ends and make sure it is not damaged or contaminated.
- If the checks are not good, repair/replace defective coaxial cable as required and do close out.
- If the checks are good, continue with next step.
- Perform a continuity check as follows:
From To Result A228CP1-12 Ground A228CP1-12 Outer connector (Shield) - If there is continuity, repair/replace defective coaxial cable as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228CP1-12 A240CP1-12 - If there is no continuity, repair/replace defective coaxial cable as required and do close out.
- If there is continuity, continue with next step.
- Replace the RFU. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the SDU.
- Do close out.