Message Overview:
Fault Message:
DATA LINK HAS NOT DECLARE ITSELF AC
Fault Code:
23100DCSC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Airborne Data-Link Unit (ADLU) cannot transmit or receive data.
Possible Causes:
The Airborne Data-Link Unit (ADLU) cannot transmit or receive data.
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Airborne Data-Link Unit | AMM 23-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Airborne Data-Link Unit | AMM 23-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect Datalink Unit connector A239CP1. Make sure the ADLU is receiving 28 VDC power at pin A239CP1-2 and a ground is present at pin A239CP1-4.
- If power and ground are good, continue with next step.
- If power or ground are not present, troubleshoot wiring or power source (SPDA 4) and do close out.
- Disconnect Datalink Unit connector A239AP1 and SDU connector A228BP1. Perform a wiring check as follows:
From To Result A239AP1-A15 Ground A239AP1-B15 Ground A239AP1-C15 Ground A239AP1-D15 Ground A239AP1-A15 A239AP1-B15 A239AP1-C15 A239AP1-D15 - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a wiring check as follows:
From To Result A239AP1-A15 A228BP1-G1 A239AP1-B15 A228BP1-H1 A239AP1-C15 A228BP1-J1 A239AP1-D15 A228BP1-K1 - If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace the ADLU. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the SDU.
- Do close out.