04/28/20
Message Overview:
Fault Message:
RFU TO SDU RF CONTINUITY FAIL/WIRIN
Fault Code:
23100E0SC
Associated CAS:
| Reporting LRU: | Satellite Data Unit (SDU) |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00[ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09[ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Satellite Communication (SATCOM) System operates incorrectly or not at all. Issue detected with the input coax of the Satellite Data Unit (SDU) from the Radio Frequency Unit (RFU).
Possible Causes:
- Radio Frequency Unit (RFU) (A240)
- Satellite Data Unit (SDU) (A228)
- Coaxial Cable
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Radio Frequency Unit | AMM 23-13-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Radio Frequency Unit | AMM 23-13-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect SDU connector A228CP1 and RFU connector A240CP1. Inspect the Coaxial cable connector on both ends and make sure it is not damaged or contaminated.
- If the checks are good, continue with next step.
- If the checks are not good, repair/replace defective coax as required and do close out.
- Perform a continuity check as follows:
From To Result A228CP1-13 Ground A228CP1-13 Outer connector (Shield) - If there is continuity, repair/replace defective coax wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A228CP1-13 A240CP1-13 - If there is continuity, continue with next step.
- If there is no continuity, repair/replace defective coax wiring as required and do close out.
- Replace the RFU. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the SDU.
- Do close out.