04/28/20
Message Overview:
Fault Message:
PWR INTERRUPT TO SDU
Fault Code:
23100FESC
Associated CAS:
| Reporting LRU: | Satellite Data Unit |
| System Description: | 23-13-00 |
| Schematic Diagram: | 23-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-13-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Satellite Data Unit (SDU) had an In-flight primary power interrupt.
Possible Causes:
- Satellite Data Unit (SDU) (A228)
- Secondary Power Distribution Assembly (SPDA) 4 (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
AW 700-23-0584 - Honeywell SDU-600 Obsolescence
AW 700-23-0756 - MCS-7000 Obsolescence
SB 700-23-001 - Modification MCS-6000 SATCOM
SB 700-23-043 - Modification MCS-7000 SATCOM
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Satellite Data Unit | AMM 23-13-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Satellite Data Unit | AMM 23-13-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect SDU connector A228CP1. Inspect all the pins and sockets on both mating sides of the connector. Make sure there are no loose, damaged or bent pins/sockets.
- If the inspection is not satisfactory, repair defective as required and do close out.
- If the inspection is satisfactory, continue with next step.
- Re-connect the SDU and test the system. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap SPDA 4 with another SPDA. Is the fault still present?
- If NO, replace SPDA 4 and do close out.
- If YES, continue with next step.
- Make sure the wiring between SPDA 4 connector A16P1-m and SDU connector A228CP1-2 is not damaged or does not have an intermittent connection. Check for short to ground as well.
- If the wiring is defective, repair defective wiring as required and do close out.
- If the wiring is good, continue with next step.
- Replace the SDU.
- Do close out.