06/14/19
Message Overview:
Fault Message:
ADLU CONFIGURATION MODULE FAULT
Fault Code:
2320002TDY
Associated CAS:
| Reporting LRU: | Airborne Data-Link Unit |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 23-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Set when configuration module access fails and cleared when configuration module access succeeds.
Possible Causes:
- Airborne Data-Link Unit (ADLU) (A239)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The configuration module cannot be accessed. Check configuration module.
Quick Links:
| Removal of the Airborne Data-Link Unit | AMM 23-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Airborne Data-Link Unit | AMM 23-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the Airborne Data-Link Unit Configuration Module. Inspect the module to make sure that the wires between Configuration Module and the ADLU are connected as follows:
Configuration Module ADLU Result TCZ 0435 Y A239AP1-C11 TCZ 0435 R A239AP1-D11 TCZ 0435 B A239AP1-C12 TCZ 0435 BN A239AP1-D12 - Are the wires between Configuration Module and the ADLU connected correctly?
- If NO, reconnect the wires between configuration module and the ADLU as per table above and do close out.
- If YES, continue with next step.
- Replace the Airborne Data-Link Unit Configuration Module (ADLU Configuration Module is faulty).
- Do close out.