Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/14/19

Message Overview:

Fault Message:

ADLU CONFIGURATION INVALID

Fault Code:

2320003TDY

Associated CAS:

None

Reporting LRU: Airborne Data-Link Unit
System Description: 23-23-00
Schematic Diagram: 23-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 23-23-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
23-23-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Airborne Data-Link Unit (ADLU) reads an invalid configuration from the configuration module. Set during power up initialization if an invalid configuration is detected.

Possible Causes:

  • Airborne Data-Link Unit (ADLU) (A239)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Check configuration module entries for validity.

Quick Links:

Removal of the Airborne Data-Link Unit AMM 23-23-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Airborne Data-Link Unit AMM 23-23-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Make sure the ADLS configuration data (ground address, aircraft type information, aircraft registration number, and communication interface data) is correct.
  2. Is the ADLS configuration data correct?

    1. If NO, enter the correct configuration data as required and do close out.
    2. If YES, continue with next step.

  3. Remove the Airborne Data-Link Unit Configuration Module. Inspect the module to make sure that the wires between Configuration Module and the ADLU are connected as follows:

    Configuration Module ADLU Result
    TCZ 0435 Y A239AP1-C11
    TCZ 0435 R A239AP1-D11
    TCZ 0435 B A239AP1-C12
    TCZ 0435 BN A239AP1-D12

  4. Are the wires between Configuration Module and the ADLU connected correctly?

    1. If NO, reconnect the wires between configuration module and the ADLU as per table above and do close out.
    2. If YES, continue with next step.

  5. Replace the Airborne Data-Link Unit Configuration Module (ADLU Configuration Module is faulty).
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.