06/14/19
Message Overview:
Fault Message:
ADLU CDU/FMS/IAC #3 FAULT
Fault Code:
2320006TDY
Associated CAS:
| Reporting LRU: | Flight Management System 3 |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 23-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Control and Display Unit (CDU)/Flight Management System (FMS)/Integrated Avionics Computer (IAC) 3 ARINC 429 broadcast data not received by Airborne Data-Link Unit (ADLU). Set when no data is received for 1 minute and cleared when data is received.
Possible Causes:
- Airborne Data-Link Unit (ADLU) (A239)
- Integrated Avionics Computer (IAC) 3 (A12)
- Flight Management System Control and Display Units (FMS CDU) 3 (A218)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Make sure that FMS is operative and there are no active/stored faults for FMS 3.
- If there are active faults related to FMS 3, troubleshoot and fix active faults before proceeding with further steps
- If there are stored faults related to FMS 3, make sure that faults did not happen at the same time as ADLU CDU/FMS/IAC #1 FAULT. If that is the case, then start with a wiring check between the Airborne Data-Link Unit (ADLU) and FMS 3 and FMS CDU 3
THIS FAULT WILL ALSO BE SEEN WHEN IAC #3 IS NOT INSTALLED. If no FMS 3 is installed, disregards the fault code.
Quick Links:
| Initialization of the Flight Management System (FMS) | AMM 34-61-00-840-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Flight Management System (FMS) | AMM 34-61-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Operate the Airborne Data-Link System via FMS 3 using VHF network to request a "dummy" flight plan provided by service provider.
NOTE: Make sure aircraft is within VHF range of ACARS data communication ground station and VHF #3 is operative. Do the initialization of the Flight Management System (FMS). - When the message FLT PLAN RECEIVED is shown on the FMS CDU 3, activate the flight plan, make sure the flight plan is loaded and the FMS CDU 2 automatically shows the ACTIVE FLT PLAN page 1/1. Is the ACTIVE FLT PLAN page 1/1 shown?
- If YES, Verify that CAIMS fault code 2320006TDY "ADLU CDU/FMS/IAC #3 FAULT" is not displayed on PMAT and do close out.
- If NO, continue with next step.
- Perform wiring checks, short to ground and pin/socket retention check between the Airborne Data-Link Unit (ADLU) connector A239AP1, connector A239BP1 and FMS 3/IAC 3 connector A12CP1 and FMS 3 CDU connector A218P1. Is it satisfactory?
- If NO, repair or replace the defective wiring as required per WM 20-12 and do close out.
- If YES, continue with next step.
- Do FMS CAIMS test. Verify that CAIMS fault code 2320006TDY "ADLU CDU/FMS/IAC #3 FAULT" is not displayed on PMAT and proceed for close out.
- Do close out.