06/14/19
Message Overview:
Fault Message:
ADLU ARINC RX 3 FAULT
Fault Code:
2320013TDY
Associated CAS:
| Reporting LRU: | Airborne Data Link Unit (ADLU) |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 23-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Airborne Data-Link Unit (ADLU) ARINC 429 Receiver 3 firmware failure.
Possible Causes:
- Airborne Data Link Unit (ADLU) (A239)
- Satellite Communication (SATCOM)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This receiver is used for the SATCOM DATA UNIT. If no SATCOM system is installed, disregard the fault code.
Quick Links:
| Removal of the Airborne Data-Link Unit | AMM 23-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Airborne Data-Link Unit | AMM 23-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Initialization of the Flight Management System (FMS) | AMM 34-61-00-840-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Do the operational test of the SATCOM system.
- Operate the Airborne Data-Link System using SATCOM network to receive the terminal text weather information. NOTE: Do the initialization of the Flight Management System.
- Is the NEW message advisory shown on FMS CDU and new message received?
- If YES, verify that CAIMS fault code 2320013TDY "ADLU ARINC RX 3 FAULT" is not displayed on PMAT and do close out.
- If NO, continue with next step.
- Perform wiring checks, short to ground and pin/socket retention check between the Airborne Data-Link Unit (ADLU) connector A239AP1 and the SDU connector A228BP1. Is it satisfactory?
- If NO, repair or replace the defective wiring as required per WM 20-12, and install the same Airborne Data-Link Unit (ADLU). Operate the Airborne Data-Link System as per step 3 in this procedure. Confirm new message received and do close out.
- If YES, continue with next step.
- Replace the Airborne Data-Link Unit (ADLU) (ADLU ARINC 429 Receiver #3 is faulty).
- Do close out.