06/14/19
Message Overview:
Fault Message:
ADLU ARINC TX 2 FAULT
Fault Code:
2320020TDY
Associated CAS:
| Reporting LRU: | Airborne Data Link Unit (ADLU) |
| System Description: | 23-23-00 |
| Schematic Diagram: | 23-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 23-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] 23-23-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Airborne Data-Link Unit (ADLU) ARINC 429 Transmitter #2 firmware failure.
Possible Causes:
- Airborne Data Link Unit (ADLU) (A239)
- Satellite Data Unit (SDU) (A228)
- Flight Management System Control-And-Display Unit (FMS CDU) 2 (A38)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This Transmitter is used for IAC/FMS 1 AND 3.
Quick Links:
| Removal of the Airborne Data-Link Unit | AMM 23-23-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Airborne Data-Link Unit | AMM 23-23-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Initialization of the Flight Management System (FMS) | AMM 34-61-00-840-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Operate the Airborne Data-Link System via FMS 1 using VHF network to request a "dummy" flight plan provided by service provider.
NOTE: Make sure aircraft is within VHF range of ACARS data communication ground station and VHF #3 is operative. Do the initialization of the Flight Management System (FMS). - When the message FLT PLAN RECEIVED is shown on the FMS CDU 1, activate the flight plan, make sure the flight plan is loaded and the FMS CDU 1 automatically shows the ACTIVE FLT PLAN page 1/1. Is the ACTIVE FLT PLAN page 1/1 shown?
- If YES, go to step 4.
- If NO, continue with next step.
- Perform wiring checks, short to ground and pin/socket retention check between the Airborne Data-Link Unit (ADLU) connector A239AP1, A239BP1 and FMS 1/IAC 1 connector A11CP1. Is it satisfactory?
- If YES, go to step 8.
- If NO, repair or replace the defective wiring as required per WM 20-12 and do close out.
- Check if FMS 3 is installed?
- If NO, verify that CAIMS fault code 2320020TDY "ADLU ARINC TX 1 FAULT" is not displayed on PMAT and do close out.
- If YES, continue with next step.
- Operate the Airborne Data-Link System via FMS 3 using VHF network to request a "dummy" flight plan provided by service provider.
NOTE: Open circuit breakers "FMS 1 CDU" and "FMS 2 CDU" on the EMS CDU. - Make sure aircraft is within VHF range of ACARS data communication ground station and VHF #3 is operative. Do the initialization of the Flight Management System (FMS). When the message FLT PLAN RECEIVED is shown on the FMS CDU 3, activate the flight plan, make sure the flight plan is loaded and the FMS CDU 3 automatically shows the ACTIVE FLT PLAN page 1/1. Is the ACTIVE FLT PLAN page 1/1 shown on FMS CDU 3?
- If YES, perform step 4 again.
- If NO, continue with next step.
- Perform wiring checks, short to ground and pin/socket retention check between the Airborne Data-Link Unit (ADLU) connector A239AP1, A239BP1 and FMS 3/IAC 3 connector A12CP1. Is it satisfactory?
- If NO, repair or replace the defective wiring as required per WM 20-12 and do close out.
- If YES, continue with next step.
- Replace the Airborne Data-Link Unit (ADLU) (ADLU ARINC 429 Transmitter #1 is faulty).
- Do close out.