Message Overview:
Fault Message:
GEN3 GENERATOR FAULT
Fault Code:
2423104LPS
Associated CAS:
| Reporting LRU: | Generator Control Unit (GCU) 3 |
| System Description: | 24-21-00 |
| Schematic Diagram: | 24-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-21-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Generator Control Unit (GCU) 3 senses a field current greater than 3 amps from Generator 3.
Possible Causes:
- Variable Frequency Generator (VFG) 3 (G3)
- Generator Control Unit (GCU) 3 (A58)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
A GCU patch cable (GSE REF # 24X-24-02) can be used to swap GCUs 1, 4 and 5 into position 2 or 3 (for troubleshooting only).
The GCU NVMs can only be downloaded at position #2 or #3.
Quick Links:
| Removal of the Variable Frequency Generators (VFG) | AMM 24-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Variable Frequency Generators (VFG) | AMM 24-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Generator Control Units (GCU) | AMM 24-24-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Generator Control Units (GCU) | AMM 24-24-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap GCU 3 with GCU 2.
- If system checks are good, replace GCU 3 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between GCU#3 connector A58P1 and Generator#3 connector G3P1 as follow:
From To Result A58P1-J G3P1-H A58P1-K G3P1-B - If wiring checks are not good, repair the defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
NOTE: Both wires should be measured open to aircraft structure.
- Replace generator 3.
- Do close out.