Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC PRIMARY LOGIC CARD #1-A18 FAIL

Fault Code:

2451303ACP

Associated CAS:

ELEC SYS FAIL
Caution

Reporting LRU: AC Power Center (ACPC)
System Description: 24-50-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

AC Power Center (ACPC) Primary Logic Card (PLC 1) has failed the power on Built-In Test or the continuous Built-In Test.

Possible Causes:

  • Primary Logic Card (PLC) 1
  • Microprocessor Card
  • AC Power Center (ACPC) (A54)

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)
Fault-Tolerant Microprocessor
AMM 24-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)
Fault-Tolerant Microprocessor
AMM 24-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Primary Logic AMM 24-51-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Primary Logic AMM 24-51-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Do a complete aircraft power reset. Is the fault still present?

    1. If NO, monitor for failure and do close out and.
    2. If YES, continue with next step.

  2. Access the ACPC logic assembly. Remove PLC 1. Inspect the cards connectors and the motherboard connector. Look for any bent or damaged contacts.

    1. If contacts are found damaged, replace defective component (ACPC or PLC) and do close out.
    2. If all contacts are good, continue with next step.

  3. Carefully reinstall PLC 1 properly. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Swap PLC 1 with PLC 2. Is the fault still present?

    1. If NO, replace PLC 1 and do close out.
    2. If YES, continue with next step.

  5. On the EMS CDU, push on "CNTL". Select the bottom left line select key (LSK) and then, select the bottom right LSK. Push on "TEST". Highlight and select "ASSEMBLY" until assembly selected is ACPC. Highlight and select "SWAP MICROPROCESSORS". Is the fault still present?

    1. If NO, replace defective Microprocessor and do close out.
    2. If YES, continue with next step.

  6. Replace ACPC.
  7. Do close out.