06/28/19
Message Overview:
Fault Message:
ACPC SECONDARY LOGIC CARD1-A7 FAIL
Fault Code:
2451306ACP
Associated CAS:
| Reporting LRU: | Secondary Logic Card (SLC) |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Logic Card has detected an internal failure.
Possible Causes:
- Secondary Logic Card (SLC) 1
- Left Microprocessor Card
- A/D Converter Card
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
The following are the main functions of SLC1:
- Control of AC 1 feeder (K15) and EHP 3B (K14) contactors.
- Current sensing and over-current protection (current > 121%) for AC 1 feeder and EHP 3B feeder.
- Control of AC 1 cabin relay (K16 and CB-B5).
- Monitors voltage presence on AC 1 bus.
- Monitors three external manually operated switches.
- EHP 3B Manual Switch.
- Left Aft Engine Run Command Switch.
- Left Aft Boost Pump Inhibit Switch.
- Monitors status of AC 1 feeder, EHP 3B feeder, AC 1 cabin relay.
- Monitor thermal circuit breakers.
- EXT AC PBA LTS (CB-A12).
- DCPC EXT CTL PWR (CB-A11).
- EMS CDU ½ PWR C (CB-A10).
- EXT AC INTERLOCK (CB-A9).
- STAB TRIM CH 1 (CB-B6).
- AC 1 CABIN FEED (CB-B5).
- Provides interface to microprocessor.
Quick Links:
| Removal of the AC Power Center (ACPC) Fault-Tolerant Microprocessor |
AMM 24-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Fault-Tolerant Microprocessor |
AMM 24-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) External AC-to-DC Converter |
AMM 24-51-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) External AC-to-DC Converter |
AMM 24-51-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SLC 1 with SLC 2, 3 or 4.
- If system checks are good, replace SLC 1 and do close out.
- If fault remains, continue with next step.
- Swap microprocessor cards.
- If system checks are good, replace defective microprocessor card and do close out.
- If fault remains, continue with next step.
- Replace AD Converter card.
- Do close out.