Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

ACPC SSPC PWR CARD1 (A2)/AFT PR PMP

Fault Code:

2451320ACP

Associated CAS:

ELEC SYS FAIL
Caution

Reporting LRU: AC Power Center (ACPC) Solid-State Power Controller (SSPC) Power Card
System Description: 24-50-00
Schematic Diagram: 24-51-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-51-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
28-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

AC Power Center (ACPC) Solid-State Power Controller (SSPC) Power Card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry, and/or the load.

Possible Causes:

  • AC Power Center (ACPC) (A54)
  • Solid-State Power Controller (SSPC) 1
  • Left AFT Boost Pump (B7)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

  • If the pump is inoperative without CAIMS message and SSPC is IN, check wires between L Wing Feed Inhibit Pri Pumps switch, LH Fuel Cutoff switch and the SLC #1
  • If the SSPC is always tripped without CAIMS message, check for a short between the pump and the SSPC #1

Quick Links:

Removal of the AC Power Center (ACPC) AMM 24-51-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) AMM 24-51-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC)
Solid-State Power Controller
AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Boost-Pump Cartridges AMM 28-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Boost-Pump Cartridges AMM 28-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SSPC 1 with SSPC 10.

    1. If system checks are good, replace SSPC 1 and do close out.
    2. If fault remains, continue with next step.

  2. Perform wiring checks between L AFT boost pump and SSPC 1.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  3. Check for short circuit to GND at SSPC 1 as follows:

    From To Result
    P120-25 Ground
    P120-28 Ground
    P120-31 Ground

    1. If short circuit is found, go to step 6.
    2. If no short circuit is found, continue with next step.
      NOTE: Disconnect L AFT boost connector B7P1 and remove SSPC 1 card for short circuit check.

  4. Check for open circuit/resistance consistency at SSPC 1 as follows:

    From To Result
    P120-25 P120-28
    P120-25 P120-31
    P120-28 P120-31

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.
      NOTE: L AFT boost connector B7P1 must be connected.

  5. Replace L AFT boost pump.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Replace ACPC.
  7. Do close out.