Message Overview:
Fault Message:
ACPC SSPC PWR CARD1 (A2)/AFT PR PMP
Fault Code:
2451320ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) Solid-State Power Controller (SSPC) Power Card |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] 28-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
AC Power Center (ACPC) Solid-State Power Controller (SSPC) Power Card has detected a failure with the initialization of the AC SSPCs, the control logic circuitry, and/or the load.
Possible Causes:
- AC Power Center (ACPC) (A54)
- Solid-State Power Controller (SSPC) 1
- Left AFT Boost Pump (B7)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- If the pump is inoperative without CAIMS message and SSPC is IN, check wires between L Wing Feed Inhibit Pri Pumps switch, LH Fuel Cutoff switch and the SLC #1
- If the SSPC is always tripped without CAIMS message, check for a short between the pump and the SSPC #1
Quick Links:
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Solid-State Power Controller |
AMM 24-51-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Boost-Pump Cartridges | AMM 28-21-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Boost-Pump Cartridges | AMM 28-21-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SSPC 1 with SSPC 10.
- If system checks are good, replace SSPC 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between L AFT boost pump and SSPC 1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Check for short circuit to GND at SSPC 1 as follows:
From To Result P120-25 Ground P120-28 Ground P120-31 Ground - If short circuit is found, go to step 6.
- If no short circuit is found, continue with next step.
NOTE: Disconnect L AFT boost connector B7P1 and remove SSPC 1 card for short circuit check.
- Check for open circuit/resistance consistency at SSPC 1 as follows:
From To Result P120-25 P120-28 P120-25 P120-31 P120-28 P120-31 - If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: L AFT boost connector B7P1 must be connected.
- Replace L AFT boost pump.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ACPC.
- Do close out.