10/02/20
Message Overview:
Fault Message:
ACPC GTC 9 CONTACTOR-K2 FAILED
Fault Code:
2451349ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The AC Power Center (ACPC) Primary Logic Cards (PLC) detect a discrepancy between coil drive status and auxiliary contact status of the contactor K2.
Possible Causes:
- AC Power Center (ACPC) Contactor (K2)
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) TB601
- AC Power Center (ACPC) TB202
- AC Power Center (ACPC) TB101
- Electronic Module 1 (EM1)
- Primary Logic Card (PLC)
- Primary Logic Card (PLC)
- Primary Logic Card (PLC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) L-Series Contactors | AMM 24-51-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Electronic Modules | AMM 24-51-81-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Electronic Modules | AMM 24-51-81-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| AC Power Center Component Maintenance Manual | CMM 24-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect contactor K2 connector P106.
- In the cockpit, turn the BATT MSTR SW to ON.
- Check for 28 Volts DC between P106 to ground as follow:
From To Result P106-1 Ground - If there is Voltage, go to step 5.
- If there is no Voltage, continue with next step.
- Perform wiring checks between EM1, TB101 and TB202 as follow:
From To Result P407 TB202-1 TB101-1 TB202-1 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- In the cockpit, turn the BATT MSTR SW to OFF.
- Perform a continuity check between K2 to ground as follows:
From To Result P106-1 Ground - If there is continuity, go to step 9.
- If there is no continuity, continue with next step.
- Check TB101-2 connection. Repair as required.
- If system checks is good, do close out.
- If fault remains, continue with next step.
- Check TB601-7 connection. Repair as required.
- If system checks is good, do close out.
- If fault remains, continue with next step.
- Remove PLC 1, PLC 2 and PLC 3.
- Perform a continuity check on K8 relay between K2 and ground as follows:
From To Result P106-8 Ground P106-22 Ground - If there is continuity, go to step 16.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P106-22 P315C-36 P106-22 P115C-36 P106-22 P415C-36 P106-8 P315B-22 P106-8 P115B-22 P106-8 P415B-22 - If there is continuity, continue with next step.
- If there is no continuity, go to step 16.
- Replace K2.
- If system check is good, do close out.
- If fault remains, continue with next step.
- Re-install PLC 2 and PLC 3.
- If system checks is good, replace PLC 1 and do close out.
- If fault remains, continue with next step.
- Remove PLC 2 and reinstall PLC 1.
- If system checks is good, replace PLC 2 and do close out.
- If fault remains, continue with next step.
- Remove PLC 3 and reinstall PLC 2.
- If system checks is good, replace PLC 3 and do close out.
- If fault remains, continue with next step.
- Replace ACPC.
- Do close out.