Message Overview:
Fault Message:
ACPC AC 2 CABIN FEED RELAY-K19
Fault Code:
2451361ACP
Associated CAS:
| Reporting LRU: | AC Power Center (ACPC) |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Secondary Logic Card 2 (SLC 2) detects a discrepancy between the coil drive status and auxiliary contact status of K19 Contactor.
Possible Causes:
- AC Power Center (ACPC) Contactor (K19)
- Secondary Logic Card (SLC) 2
- Electronic Module (EM1)
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) TB202
- AC Power Center (ACPC) TB601
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) K-Series Relays (K16, K19, K23 and K26) |
AMM 24-51-69-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) K-Series Relays (K16, K19, K23 and K26) |
AMM 24-51-69-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Electronic Modules | AMM 24-51-81-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Electronic Modules | AMM 24-51-81-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| AC Power Center Component Maintenance Manual | CMM 24-51-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SLC 2 with SLC 1.
- Perform a voltage check on K19-X1, K19-Y1 and ground.
- If there is no voltage and there are no CAIMS messages related to EM1 fuses (F1, F2, F3 and F4), verify TB202-3.
- If there is no voltage and there are CAIMS messages related to EM1 Fuses (F1, F2, F3 and F4), troubleshoot these messages first.
- If there is 28 VDC, remove SLC 2 and disconnect K19-X1, K19-X2, K19-Y1, K19-Y2, K19-11 and K19-12.
- Perform a continuity check between the connections that follows:
From To Result K19-11 (lug) Ground - If there is no continuity, check the connection of TB202-7 and TB601-6 and repair defective wiring as required and do close out.
- If there is continuity, continue with the next step.
- Perform a continuity check between the connections that follows:
From To Result K19-Y2 (lug) Ground K19-X2 (lug) Ground K19-12(lug) Ground - If there is continuity, replace ACPC and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check between the connections that follows:
From To Result K19-Y2 (lug) SLC 2 P211A-12 K19-X2 (lug) SLC 2 P211A-13 K19-12 (lug) SLC 2 P211C-17 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace K19.
- Do close out.