Message Overview:
Message Name:
CDU 1/ACPC LEFT FTM-A20/WRG
Message Code:
2451370ACP
| Reporting LRU: | Electrical Management System Control-and-Display Unit (EMS CDU) 1 |
| Associated CAS: | ELEC SYS FAULT (Advisory) |
| System Description: | 24-50-00 - AC Electrical Load Distribution |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-00 |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 24-51-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-00 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-01 [ Global Express ] [ G5000 ] [ Global XRS ] 24-70-03 |
Message Description:
ARINC 429 communication between the AC Power Center (ACPC) and the Electrical Management System Control-and-Display Unit (EMS CDU) is faulty. The LRU transmits on periodic basis a test label that is turned around by the receiving LRU.
Possible Causes:
- Electrical Management System Control-and-Display Unit (EMS CDU) 1 (A94)
- AC Power Center (ACPC) Microprocessor Card
- AC Power Center (ACPC) (A54)
- ACPC Supervisor Card
- Junction Box (JB3)/PCB3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None.
Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
- Make sure the Junction Box #3 is racked properly. Field experience revealed many cases of Junctions Boxes not installed properly.
- Flight Deck Effect:
- AC synoptic page is all magenta.
- DC synoptic page has magenta APU battery related info.
- On the EMS CDU, ACPC electrical loads are dashed.
- Alternative Fault Confirmation And Data Gathering
- On EMS CDU 1, select Diagnostic mode:
- Select SYSTEM - CNTL key (page 1/3).
- Select lower left side key.
- Select lower right side key.
- On EMS CDU 1, select CIRCUIT BREAKER - SYS key and COUNTERS:
- On EMS CDU 1, select Diagnostic mode:
Quick Links:
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Fault-Tolerant Supervisor | AMM 24-51-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Fault-Tolerant Supervisor | AMM 24-51-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Fault-Tolerant Microprocessor | AMM 24-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Fault-Tolerant Microprocessor | AMM 24-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Primary Logic | AMM 24-51-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Secondary Logic | AMM 24-51-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) AC External-Power Quality Monitor | AMM 24-51-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) AC External-Power Quality Monitor | AMM 24-51-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) Solid-State Power Controller | AMM 24-51-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) Solid-State Power Controller | AMM 24-51-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Interchange EMS CDU 1 with EMS CDU 2.
- If system checks are good, replace EMS CDU 1 and do close out.
- If fault remains, continue with the next step.
- Interchange ACPC microprocessor cards. Is the fault present?
- If NO, replace defective ACPC microprocessor card and do close out.
- If YES, continue with next step.
- Disconnect EMS CDU 1 connector A94P1. Remove both ACPC microprocessor cards.
EMS CDU To ACPC Schematic 
- Do Wiring checks as follows:
From To Expected Result Result A94P1-5 Ground Open A94P1-6 Ground Open A94P1-7 Ground Open A94P1-8 Ground Open - Are results satisfactory?
- If YES, go to step 8.
- If NO, continue with the next step.
- Disconnect ACPC connector A54P6. Do Wiring checks as follows:
From To Expected Results Result A94P1-5 Ground Open A94P1-6 Ground Open A94P1-7 Ground Open A94P1-8 Ground Open - Are results satisfactory?
- If YES, continue with the next step.
- If NO, repair defective wiring as required and do close out.
- Perform a continuity check between the EMS CDU and the ACPC Microprocessor cards as follows:
From To Result A94P1-5 P2A-23 A94P1-6 P2B-23 A94P1-7 P2A-22 A94P1-8 P2B-22 A94P1-7 P3A-22 A94P1-8 P3B-22 - If there is continuity, replace ACPC Supervisor Card.
- If there is no continuity, continue with the next step.
- Disconnect ACPC Connector A54P6. Perform a continuity check as follows:
From To Result A94P1-5 A54P6-V A94P1-6 A54P6-W A94P1-7 A54P6-R A94P1-8 A54P6-S - If there is continuity, continue with the next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace ACPC.
- Do close out.