06/28/19
Message Overview:
Fault Message:
CCBP ETTC-K2/DCPC RELAY-K12
Fault Code:
2460483DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-50-00 |
| Schematic Diagram: | 24-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-52-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Primary Logic Cards have determined that the ETTC status does not match its commanded state.
Possible Causes:
- Cockpit Circuit-Breaker Panel (CCBP) ETTC Contactor (K2)
- DC Power Center (DCPC) Relay (K12)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- DC Power Center (A63)
- Battery Ram-Air-Turbine Interface (BATT/RAT IF) Card
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cockpit Circuit-Breaker Panel (CCBP) H-Series Contactors | AMM 24-52-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cockpit Circuit-Breaker Panel (CCBP) H-Series Contactors | AMM 24-52-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Battery/Ram-Air-Turbine Interface Unit | AMM 24-61-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) J-Series Relay | AMM 24-61-57-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) J-Series Relay | AMM 24-61-57-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove power from the A/C. Access K2 in the CCBP. Perform a continuity check as follows:
From To Result K2-11 K2-12 K2-A1 K2-A2 K2-B1 K2-B2 K2-C1 K2-C2 - If there is continuity on one or more of the above checks, replace K2 and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K2-X1 K2-A1 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue next step.
- Disconnect ETTC K2-12. Access the DCPC logic assembly and remove all three PLC. Perform a continuity check as follows:
From To Result K2-12 Ground - If there is continuity, repair defective aircraft wiring as required or replace DCPC if defect is inside the DCPC and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K2-12 P110B-34 K2-12 P210B-34 K2-12 P310B-34 - If there is no continuity, repair defective aircraft wiring as required or replace DCPC if defect is inside DCPC and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K2-11 Ground - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perfom a continuity check as follows:
From To Result K2-X2 Ground - If there is continuity, repair defective wiring as required or replace DCPC if defect is inside DCPC and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check between K2 (CCBP) and K12 (DCPC) as follows:
From To Result K2-X2 K12-B2 - If there is no continuity, repair defective aircraft wiring as required or replace DCPC if defect is inside the DCPC and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K12-B1 K12-B2 - If there is continuity, replace K12 and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K12-B1 Ground - If there is no continuity, verify connection and if properly connected, replace DCPC and do close out.
- If there is continuity, continue with next step.
- Remove the BATT/RAT IF card from the DCPC Logic assembly. Perform a continuity check as follows:
From To Result K12-X1 Ground K12-X2 Ground - If there is continuity, replace DCPC and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result K12-X1 P410A-48 K12-X2 P110C-12 K12-X2 P210C-12 K12-X2 P310C-12 - If there is no continuity, replace DCPC and do close out.
- If there is continuity, continue with next step.
- Reconnect any component that was disconnected during troubleshooting. Reinstall the BATT/RAT IF Card. Reinstall PLC 2 and PLC 3 only. Apply power to the A/C. Is the fault still present?
- If NO, replace the PLC 1 and do close out.
- If YES, continue with next step.
- Remove power from the A/C. Remove PLC 2 and reinstall PLC 1. Apply power to the A/C. Is the fault still present?
- If NO, replace the PLC 2 and do close out.
- If YES, continue with next step.
- Remove power from the A/C. Remove PLC 3 and reinstall PLC 2. Apply power to the A/C. Is the fault still present?
- If NO, replace the PLC 3 and do close out.
- If YES, continue with next step.
- Remove power from the A/C. Access ETTC K2 in the CCBP. Apply power to the A/C. On the EMSCDU, push on the red “EMER CONT” button and turn AC 1 to 'OFF'. Perform a continuity check as follows:
From To Result K12-X2 Ground - If there is continuity, replace K2 and do close out.
- If there is no continuity, continue with next step.
- Replace the BATT/RAT IF card.
- Do close out.