06/21/19
Message Overview:
Fault Message:
DCPC[FIREX B 5A EMERG. BUS]/WRG
Fault Code:
261003CWK
Associated CAS:
| Reporting LRU: | Fire Detection and Extinguishing Control Unit (FIDEEX CU) |
| System Description: | 26-21-00 |
| Schematic Diagram: | 26-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 26-10-01 [ Global Express ] [ G5000 ] [ Global XRS ] 26-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Fire Detection and Extinguishing Control Unit (FIDEEX CU) has no power from DC Power Center (DCPC) (Fire-Detection-and-Extinguishing (FIREX) Bottle D).
Possible Causes:
- DC Power Center (DCPC) (A63)
- Fire Detection and Extinguishing Control Unit (FIDEEX CU) (A106)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Fire-Detection-and-Extinguishing (FIDEEX) Control-Unit | AMM 26-10-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Fire-Detection-and-Extinguishing (FIDEEX) Control-Unit | AMM 26-10-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure FIDEEX CU circuit breakers are set to in.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure for 28 VDC at FIDEEX CU (A106P2).
- If there is 28 VDC, go to step 5.
- If there is no 28 VDC, continue with next step.
- Perform a wiring check between FIDEEX CU (A106P2) and DC Power Center (A63P4).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace DC Power Center (DCPC).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FIDEEX CU.
- Do close out.