06/24/19
Message Overview:
Fault Message:
SFCU #1/SFCU #2/WRG/SPC CH A I/F
Fault Code:
2730104STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Channel A of the Stall Protection Computer receives no ARINC labels from Slat/Flap Control Unit (SFCU) 1 or SFCU 2.
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Slat/Flap Control Unit (SFCU) 2 (A95)
- Stall Protection Computer (SPC) Channel A
- Stall Protection Computer (SPC) (A40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to the active faults for SFCU 1 and SFCU 2. Check if there is any internal fault for SFCU 1 or SFCU 2.
- If there is an internal fault for SFCU 1 or SFCU 2, replace applicable SFCU and do close out.
- If there is no internal fault for SFCU 1 or SFCU 2, continue with next step.
- On the CAIMS PMAT, get access to the active faults for SPC 1 and SPC 2. Did you record CAIMS - SFCU #1/SFCU #2/WRG/SPC CH A I/F?
- If NO, do close out.
- If YES, continue with next step.
- Perform wiring checks between SFCU 1 (A124AP1) and SPC Channel A (A40AP1); and between SFCU 2 (A95AP1) and SPC Channel B (A40BP1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace SPC.
- Do close out.