06/25/19
Message Overview:
Fault Message:
AOA#1[SIGNAL 2]/SPC CH A
Fault Code:
2730209STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
When one of the conditions that follow occurs:
- Stall Protection Computer (SPC) Channel A does not receive data from the Angle-Of-Attack (AOA) Sensor 1
- Data from AOA Sensor 1 (resolver 2) received by SPC Channel A does not agree with the data from AOA sensor 2 received by SPC Channel B
- Data from the Angle-Of-Attack Sensors received by SPC Channel B is not correct
NOTE: When a single AOA Sensor and signal is specified without the combination "AOA #1/AOA #2/WRG/SPC CH X", then the SPC senses that the specified AOA has a failure but can operate on the remaining functional resolver signal.
Possible Causes:
- Angle-Of-Attack (AOA) Sensor 1 (MT136)
- Stall Protection Computer (SPC) (A40)
- Stall Protection Computer (SPC) Channel A
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Angle-of-Attack Sensor | AMM 27-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Angle-of-Attack Sensor | AMM 27-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap AOA 1 with AOA 2.
- If system checks are good, replace AOA 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between AOA 1 and SPC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Stall Protection Computer (SPC).
- Do close out.