Message Overview:
Fault Message:
ADC #2/ADC #3/WRG/SPC CH B I/F
Fault Code:
2731101STL
Associated CAS:
| Reporting LRU: | Stall Protection Computer (SPC) |
| System Description: | 27-32-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-32-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Channel B of the Stall Protection Computer (SPC) receives no ARINC labels from the Primary or Secondary Micro Air Data Computer (MADC).
Possible Causes:
- Micro Air Data Computer (MADC) 2 (A28)
- Micro Air Data Computer (MADC) 3 (A29)
- Stall Protection Computer (SPC) (A40)
- Stall Protection Computer (SPC) Channel B
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Micro Air-Data Computers | AMM 34-11-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Micro Air-Data Computers | AMM 34-11-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if any one of the following CAS messages are posted.
- If one of the CAS messages are posted, troubleshoot them first.
- If no CAS messages are posted, continue with next step.
- Swap MADCs.
- If system checks are good, replace the defective MADC and do close out.
- If fault remains, continue with next step.
- Perform wiring checks MADC 2 (A28P1) and SPC (A40BP1); and between MADC 3 (A29P1) and SPC (A40BP1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Stall Protection Computer (SPC).
- Do close out.