08/19/19
Message Overview:
Fault Message:
BMC_1A INVALID
Fault Code:
3141049DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 30-11-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 1 is reporting that the LRU is transmitting label 270 with incorrect Source Destination Identifier (SDI) or invalid SSM (Failure warning or no computed data). If this fault shows at the same time as an "INACTIVE" fault for the same LRU, ignore this fault because the "INACTIVE" condit.
Possible Causes:
- Bleed Management Controller (BMC) 1 (A69)
- Data Acquisition Unit (DAU) 1 (A17)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None