08/21/19
Message Overview:
Fault Message:
BMC_2A/WRG/DAU #3 INACTIVE
Fault Code:
3145050DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 30-11-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Fault Description:
Data Acquisition Unit (DAU) 3 is reporting that one of the following is at fault:
- The DAU 3 ARINC recevier (Internal failure)
- The transmitter of the LRU wired to DAU 3 (See below for LRU identification)
- ARINC wiring interfacing DAU 3 and LRU
According to DAU position, LRU is.
Possible Causes:
- Data Acquisition Unit (DAU) 3 (A30)
- Bleed Management Controller (BMC) 2 (A70)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
None
Troubleshooting Recommendations:
None