08/21/19
Message Overview:
Fault Message:
FWC 2 - LASERTRAK FAULT
Fault Code:
3151016FW2
Associated CAS:
| Reporting LRU: | Fault Warning Computer (FWC) |
| System Description: | 34-46-00 |
| Schematic Diagram: | 34-46-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-46-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Fault Warning Computer (FWC) senses a malfunction in the LASER TRAK System.
Possible Causes:
- Inertial Reference System (IRS) 2
- Navigation Display Unit (NDU) (M2)
- Integrated Avionics Computer (IAC) 2 (A10)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up |
AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to system diagnostics (AMM TASK 45-45-00-970-804).
- Peform the IMT fault code look-up procedure (AMM TASK 45-45-00-970-826) and go to the fault type (4600) for the applicable troubleshooting procedures.
- Carry out troubleshooting procedures.
- Do close out.