Message Overview:
Fault Message:
OXYGEN LO QTY
Fault Code:
0000OXLY
Associated CAS:
| Reporting LRU: | Oxygen System |
| System Description: | 35-20-00 |
| Schematic Diagram: | 35-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 35-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Oxygen pressure has fallen to a low level below 1,400 psi (75%), an Oxygen Bottle Pressure Switch is indicating < 45 psi (bottle discharge), a failed Pressure Switch, a Shutoff Valve has been left closed following maintenance action.
Possible Causes:
- Oxygen Storage Cylinder
- Pressure Transducer (MT132)
- Pressure Switch (S48)
- Data Acquisition Unit (DAU) 3 (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Oxygen Pressure Transducer | AMM 35-12-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Oxygen Pressure Transducer | AMM 35-12-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Oxygen Pressure Switch | AMM 35-12-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Oxygen Pressure Switch | AMM 35-12-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 3 with DAU 4.
- If system checks are good, replace DAU 3 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between DAU 3, Oxygen Pressure Transducer, Oxygen pressure switches and SPDA 1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace defective Oxygen pressure switch.
- If system checks are good, do close out.
- If fault remains, continue with next step
- Replace Oxygen Pressure Transducer.
- Do close out.