Message Overview:
Message Name:
LEFT ICE DETECTOR /WIRING
Message Code:
3615423BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 1 |
| System Description: | 30-81-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Ice Detector 1 is reporting itself defective to Bleed Management Controller (BMC) 1. Inhibited during Take-Off and Landing.
Possible Causes:
- Ice Detector (ID) 1 (E48)
- Bleed Management Controller (BMC) 1 (A69)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0292 - Ice Detector
- AW700-36-0365 - Bleed Management Controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
Questionnaire for replacing the BMC. Follow instructions using this (Fill out form).
NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.
Quick Links:
| Removal of the Ice Detectors | AMM 30-81-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ice Detectors | AMM 30-81-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between BMC 1 and Ice Detector 1.
From To Result A69P2-27 E48P1-4 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Interchange BMC 1 with BMC 2.
- If system checks are good, replace BMC 1 and do close out.
- If fault remains, continue with next step.
- Replace Ice detector 1.
- Do close out.
NOTE:
- Ice Detector Status can be monitored into CAIMS.
- Perform alternate test for this fault if the criteria stated in AW700-30-0292 is met.