Message Overview:
Message Name:
RIGHT ICE DETECTOR /WIRING
Message Code:
3616423BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 2 |
| System Description: | 30-81-00 |
| Schematic Diagram: | 27-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Ice Detector 2 is reporting itself defective to Bleed Management Controller (BMC) 2. Inhibited during Take-off and Landing.
Possible Causes:
- Ice Detector 2 (E49)
- Bleed Management Controller (BMC) 2 (A70)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-30-0292 - Ice Detector
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.
Quick Links:
| Removal of the Ice Detectors | AMM 30-81-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ice Detectors | AMM 30-81-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between BMC 2 connector A70P2 and Ice Detector 2 connector E49P1 as follow:
From To Result A70P2-27 E49P1-4 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Interchange BMC 2 with BMC 1.
- If system checks are good, replace BMC 2 and do close out.
- If fault remains, continue with next step.
- Replace Ice detector 2.
- Do close out.
NOTE:
- Ice Detector Status can be monitored into CAIMS.
- Perform alternate test for this fault if the criteria stated in AW700-30-0292 is met.