09/16/19
Message Overview:
Fault Message:
OPEN CKT- LCV/LCV TORQUE MOT WIRING
Fault Code:
4960213APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-50-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Load Control Valve Torque Motor signals from the Full-Authority Digital Engine-Controller (FADEC) are lower than the usual values. This shows a possible open circuit in the Load Control Valve Torque Motor, the engine branched wiring-harness or the aircraft wiring harness.
Possible Causes:
- Load Control Valve (MPE1)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Load Control Valve | AMM 49-52-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Load Control Valve | AMM 49-52-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If there is bare wiring, kinks, worn areas or other damage, go to step 10.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Examine the load control valve (MPE1) receptacle for contamination and damage.
- If there is contamination or damage, go to step 11.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a continuity check on the load control valve connector (MPE1) receptacle (WM 49-12) as follows:
From To Expected Result Result MPE1P1-A MPE1P1-B 65 - 85 ohms - If resistance check fails, go to step 11.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a insulation resistance check on load control valve (MPE1) as follows (WM 49-12):
From To Expected Result Result MPE1P1-A Ground >1 megohm MPE1P1-B Ground >1 megohm - If resistance check fails, go to step 11.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a insulation resistance check on APU connector (P802) as follows (WM 49-12):
From To Expected Result Result P802-21 P802-22 >1 megohm - If resistance check fails, go to step 10.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a insulation resistance check on APU connector (P802) as follows (WM 49-12):
From To Expected Result Result P802-21 Ground >1 megohm P802-22 Ground >1 megohm - If resistance check fails, go to step 10.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a insulation resistance check on FADEC connector (A108AP1) as follows (WM 49-61):
From To Expected Result Result A108AP1-J1 A108AP1-K1 >1 megohm - If resistance check fails, repair defective wiring as required and do close out.
- If OPEN CKT-LCV/LCV TORQUE MOT WIRING still shows on CAIMS PMAT, continue with next step.
- Perform a insulation resistance check between aircraft wiring harness connector (J802) and FADEC connector (A108AP1) as follows (WM 49-61):
From To Expected Result Result J802-21 Ground >1 megohm J802-22 Ground >1 megohm A108AP1-J1 Ground >1 megohm A108AP1-K1 Ground >1 megohm - If resistance check fails, repair defective wiring as required and do close out.
- If checks are good, continue with next step.
- Replace FADEC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace engine branched wiring-harness.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace load control valve.
- Do close out.