09/20/19
Message Overview:
Fault Message:
SHORT CIRCUIT - SURGE VALVE/WIRING
Fault Code:
4960300APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-50-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The signals from the surge valve solenoid to the Full-Authority Digital Engine-Controller (FADEC) are out of the expected range. This shows a possible short-circuit in the Surge Valve Solenoid or the signal lines to the FADEC.
Possible Causes:
- Auxiliary Power Unit (APU) Full-Authority Digital Engine-Controller (FADEC) (A108)
- Surge Control Valve (MPE2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine Branched Wiring-Harness | AMM 49-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine Branched Wiring-Harness | AMM 49-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Surge Valve | AMM 49-51-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Surge Valve | AMM 49-51-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).
- If there is bare wiring, kinks, worn areas or other damage, replace Engine branched wiring-harness and do close out.
- If there is no bare wiring, kinks, worn areas or other damage, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, examine the surge valve (MPE2) receptacle for contamination and damage.
- If there is contamination or damage, go to step 10.
- If there is no contamination or damage, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, perform a continuity check within the surge valve (MPE2) receptacle (WM 49-12). The resistance should measure as follows:
From To Expected Result Result MPE2P1-A MPE2P1-B 38-46 ohms - If the resistance is not as mentioned above, go to step 10.
- If the resistance is as mentioned above, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, make sure there is no short between each of the pins A, B, and C and the connector shell of MPE2 receptacle.
- If shorts are found, go to step 10.
- If shorts are not found, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, perform a continuity check within the MPE2P1 connector as follows:
From To Result MPE2P1-A MPE2P1-B - If there is no continuity, replace Engine branched wiring-harness and do close out.
- If there is continuity, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, make sure there is no short within the connector shell of P1 as follows:
From To Result P802-65 P802-66 - If shorts are found, replace Engine branched wiring-harness and do close out.
- If shorts are not found, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, perform a continuity check within the J802 connector (WM 49-61). The resistance should measure as follows:
From To Expected Result Result J802-65 J802-66 >1 megohm - If the resistance is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance is as mentioned above, continue with next step.
- If SHORT CIRCUIT-SURGE VALVE/WIRING still shows on the CAIMS PMAT, perform a check for continuity between each pin that follows and the shell (WM 49-61). The resistance should measure as follows:
From To Expected Result Result J802-65 Ground >1 megohm J802-66 Ground >1 megohm A108BP1-C1 Ground >1 megohm A108BP1-D1 Ground >1 megohm - If the resistance is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance is as mentioned above, continue with next step.
- Replace Surge Control Valve (MPE2).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FADEC.
- Do close out.